2014年11月7日星期五

Professional Gas Permeation Tester

Labthink develops and provides professional gas permeation tester for packaging materials.

Based on different test methods, Labthink has two kinds of gas permeation testers -- equal pressure testers and differential pressure testers.

Basically, equal pressure method is used oxygen sensor to measure oxygen permeability through a specimen. OX2/230 Gas Permeability tester is based on this test method and adopts labthink lastest patent design -- three test cells in one instrument.


VAC series gas permeation testers are right based on differential pressure method and has three models -- VAC-V1, VAC-V2, VAC-V3 because they can test different number of specimen.

Labthink Instruments Co., Ltd
144 Wuyingshan Road, Jinan, P.R.China
Phone:+86-531-85068566
FAX:+86-531-85812140
Email:trade.en@labthink.cn
Website:http://www.labthinkinternational.com.cn

2014年5月6日星期二

Oxygen Transmission Rate (OTR) Testing for Breathable Packaging

When packaging oxygen-sensitive food products, such as produce meat, maintaining the product’s freshness and shelf life is of high concern. The atmospheric conditions inside of a package contribute directly to the success or failure of preserving perishable goods. Modifying the internal environment of the package, such as the levels of moisture, oxygen, and carbon dioxide, will slow down the naturally occurring deterioration process, preserving the product’s fresh state for a longer period of time.
While there are several different methods for controlling this exchange of gases, using laser micro-perforating as a breathable packaging production solution will deliver the precise oxygen transmission rate required for each individual product.
Measuring OTR
The oxygen transmission rate (OTR) is a calculated measurement of the amount of oxygen gas that, over a given period of time at a steady rate, passes through a substrate.  Oxygen transmission rates are expressed in cc/m²/24 hours (cc/100in²/24 hours), and are used to give value to the oxygen barrier capabilities of a flexible packaging film. A film that is considered to have a high barrier has an oxygen transmission rate range of approximately 1-10 cc/m²/24 hours. A moderate transmitter film will have a rate of approximately 1,000 cc/m²/24 hours, and a high transmitter film will have an oxygen transmission rate of approximately 10,000 cc/m²/24 hours.
OTR Testing Process
The OTR testing process at Labthink Instruments Company is based on ASTM D3985 — Standard Test Method for Oxygen Gas Transmission Rate throuhg Plastic Film and Sheeting using a Coulometric Sensor.  Using an PERME 230 Oxygen Transmission Rate Test System, nitrogen is flushed through a chamber where the film sample has been placed. The film in the chamber separates the nitrogen on one side from the oxygen on the other side. Oxygen molecules move through the film to the low pressure side, with the film barrier determining the rate of the oxygen transmission




Labthink Instruments has experience in the development, testing, and laser converting of breathable packaging for a wide variety of products. From achieving extremely high oxygen transmission rates of 10,000 for the fish industry, to very low rates of 300 for apples, Labthink Instruments is prepared to help you find just the right pattern and size combination to achieve the exact rate for your product

Whether you have a question regarding the OTR testing process, or if you’ve already identified an OTR that you wish to achieve, contact Labthink Instruments Company to find out how our OTR testing and laser micro-perforating services will benefit you, your product, and your customer.

2014年4月28日星期一

Rolling Ball Tack Tester - Primary Adhesion Tester for Adhesive Tapes

The rolling ball tack test is one measure of the capacity of the adhesive to form a bond with the surface of another material upon brief contact under virtually no pressure.

Rolling ball tack test is one method of attempting to quantify the ability of an adhesive to adhere quickly to another surface.

Labthink CZY-G  Primary Adhesive Tester is the right equipment, which is based on rolling ball tack test method.



Related Adhesive Tester
CZY-6S Lasting Adhesive Tester

2014年3月10日星期一

Labthink Permeability Proficiency Service Spring 2014 was officially opened

Currently various standards and test methods are applied in the permeability testing of films. However, there is no uniform standard for the accuracy of the test data. As a result, it is hard to evaluate the competency of the testing organizations or laboratories, which has become an obstacle in quality control for the film manufacturers and users. In order to provide a valuable reference for the data accuracy, Labthink launched the permeability proficiency service, which was officially opened on March 1, 2014. Labthink Permeability Proficiency Service Spring 2014 is totally free of charge. The test data will be kept confidential.

All the participants can visit Labthink official website, www.labthinkinternational.com.cn and download Permeability Proficiency Service Application Form Spring 2014, Sample Status Confirmation Form and Test Results Form from March 1, 2014 to May 1, 2014. The application form should be completed and sent to lab@labthink.cn. On receipt of the application forms, Labthink Packaging Safety Testing Center will send a unique test lab No., test samples and SOP for Permeability Proficiency Service to all the participants. The tests should be performed according to the instructions in SOP.  The Sample Status Confirmation Form and Test Results Form should be completed and sent to lab@labthink.cn before May 30, 2014. The permeability service report will be issued in the middle of June, 2014 and sent to the designated email addresses of all the participants.
Consulting service will be provided to the laboratories that submit abnormal testing data in the permeability service. The consultants invited by Labthink will help solve the problems faced by the related participants.
All the organizations and laboratories in related industries are welcome to participate in this event.
For further information, please visit the following link.
http://www.labthinkinternational.com.cn/testing/permeability-proficiency-service.html

2014年3月3日星期一

Labthink Permeability Proficiency Service

1. Background and Introduction

Scientific data is usually obtained through measurements. The competency of a laboratory is evaluated by the accuracy of its testing data. For the same test item, distinct test principles or test methods may be used by the test operators. However there is no one uniform standard by which the accuracy of the test results can be evaluated. Some laboratories which own the testing instruments to test OTR and WVTR of the films also face this problem. It has become an obstacle in R&D, quality control and standard drafting for the film manufacturers. By now, most of the laboratories evaluate their test results through inter-laboratory comparisons.
Today the testing technology and testing instruments for barrier properties are developing dramatically. In order to provide a valuable reference value for data accuracy, Labthink will launch its bi-annual permeability proficiency service since 2014. Some experts in packaging industry are invited as our consultants to guarantee the accuracy and fairness of this event..
Sincerely invite you to participate in Labthink Permeability Proficiency Service!

2. Registration Time

From March 1, 2014 to May 1, 2014

3. Test Items & Test Standards

Test ItemTest MethodTest standard
Water Vapor TransmissionGravimetric methodISO 2528:1995Sheet materials--Determination of water vapour transmission rate -- Gravimetric (dish) method
ASTM E96/E96M-12Standard Test Methods for Water Vapor Transmission of Materials
Electrolytic detection sensor methodISO 15106-3:2003Plastics -- Film and sheeting -- Determination of water vapour transmission rate --Part 3: Electrolytic detection sensor method
Infrared detection sensor methodISO 15106.2:2003Plastics -- Film and sheeting -- Determination of water vapour transmission rate -- Part 2: Infrared detection sensor method
ASTM F1249-13Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor
Humidity detection sensor methodASTM E398-13Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement
ISO 15106.1:2003Plastics -- Film and sheeting -- Determination of water vapour transmission rate -- Part 1: Humidity detection sensor method
Oxygen Gas TransmissionDifferential- pressure methodASTM D1434-82(2009)e1Standard Test Method for Determining Gas Permeability Characteristics of Plastic Film and Sheeting
ISO 15105.1-2007Plastics -- Film and sheeting -- Determination of gas-transmission rate --Part 1: Differential-pressure methods
Equal-pressure methodASTM D3985-05(2010)e1Standard Test Method for Oxygen Gas Transmission Rate Through Plastic Film and Sheeting Using a Coulometric Sensor
ISO 15105-2:2003Plastics -- Film and sheeting -- Determination of gas-transmission rate -- Part 2: Equal-pressure method

4. How to Register

Please download Permeability Proficiency Service Application Form Spring 2014 (Please find it in Document). Please complete the application form and send it to lab@labthink.cn before the deadline for registration, May 1, 2014.

For more information about Labthink Permeability Proficiency Service, please visit 
http://www.labthinkinternational.com.cn/testing/permeability-proficiency-service.html

2014年2月13日星期四

Headspace Gas Analysis and Quality Control

Oxygen and water vapor is the main factors influencing the product shelf-life. Some study found that, by controlling the composition ratio of the gas inside the packaging, products shelf-life can be extended or at least the quality of products can be improved. This has become the impetus of the rapid development and applications of barrier films. However, it is worth noting that the leak of gas filling inside the packaging (MAP and CAP packaging barely use oxygen to fill) will cause the increase in the proportion of oxygen. Furthermore, when filling in is completed, there will be a small amount of air remaining. Therefore the actual composition of the gas will be different from what expected. What would this problem cause? How to solve these problems? This article will analyze the relationship between the headspace gas analysis and the quality control of product packaging. The purchase tips of headspace gas analyzer will also be touched on.
1 The Purpose of Headspace Gas Analysis
There is also gas inside of the packaging, such as style snacks, baked goods, meat products, dairy products, coffee, fruit juice, carbonated drinks, pills, injections, per os medical liquid, perfumes, toiletries and so on. Even the so-called ‘Vacuum-packed’, it is just to reduce the gas content in packaging as much as possible. Gas can not be completely ruled out. It is very difficult to use techniques to control and change the gas composition since the end of the filling until the open of package. Use of packaging materials can only be the barrier to the infiltration of gas. Packaging cannot eliminate the in-house gases such as oxygen (excluding the oxygen elimination packaging technology). Therefore, if oxygen or other products-sensitive gas still exists inside of the package, it will impact the quality of products and gradually changes the in-house gas composition. In order to minimize the specific content of the gas, MAP and CAP packaging is widely used. The inert gas is also critical to extend shelf-life of products. It is mainly carbon dioxide and nitrogen. But as the extension of storage time, gas will constitute a gradual change. We can see that, regardless of what is the form of packaging, it is always difficult to control the internal components of the gas. So that it became difficult to analyze product quality, expected durability, and the reasonableness of the packaging design. Headspace gas analysis - testing the composition of accumulated gas, which is in the headspace inside of the packaging, can be an effective solution to this problem. It has become a test of the packaging design quality, as well as an important means to verify product shelf-life.
2 Keys to Headspace Gas Analysis
Oxygen and carbon dioxide is the key point to headspace gas analysis.
Oxygen can not only damage the nutritional content of food (for example oxygen can oxidize oils and fats, it smells bad. Sometimes it is toxic). Under most circumstances, it is the conditions for the growth of bacteria (bacteria growth in food is the main reason for deterioration). But when the oxygen content is less than 2%, carbon dioxide levels in more than 7%, food and bacteria are in a state of hibernation, which can effectively extend the shelf life of food. Many drugs, such as low-cost iron salt, iodide, nitrite, unsaturated carbon chain and other types of organic drugs, can be slowly oxidized. Discoloration, smell, decomposition and deterioration will occur. Sometimes it is also toxic. Most of cosmetics contain fat ingredients. Non-saturated fat can easily cause oxidation and deterioration (rancidity), and oxygen is the most important external cause to rancidity.
Carbon dioxide gas is an important component to CAP packaging and MAP packaging. Its content is closely related to product shelf life length, and carbon dioxide content of the package is directly influencing carbonated drinks taste and quality. Drugs packaging also needs attention to the impact of carbon dioxide, because some drugs can combine with carbon dioxide in the air, resulting in deterioration. Examples are some hydroxide, oxide and the class of calcium drugs. They can absorb carbon dioxide and produce carbonate.

Main Testing Items of BOPP Films

During manufacturing process, several organic and inorganic substances are added to the tobacco, which may generate microorganisms and mould with the changing of the storing environment. When smoking, various microorganisms and mould may change into toxins by the high temperature burning, and put threats to human health. Thus, the storage period of cigarette depends heavily on the environment: two to three year’s storage period in suitable environment, and less than one year in inferior environment. We must take cigarette packaging and storing environment into consideration, so as to prolong shelf-life period and to reduce cigarette deterioration.
1. The Analysis of Testing Demands
Temperature and humidity are the two vital factors affecting cigarette storage. Since cut tobacco would absorb moisture in high humidity environment, and would occur over-drying in low humidity environment, it’s normally required to store the cigarette in low temperature environment with proper humidity. Therefore, moistening and moldiness are the main factors affecting the quality guarantee period; and flavor protection is of vital importance, especially for high-end cigarettes. At the same time, cut tobacco is apt to absorb other aromas around which would lead to inferior cigarette flavors.
Different from other consuming products, even the retail package of cigarette has several layers, including the inner aluminum-foil paper, flexible/rigid paper packaging, and the outer transparent plastic film packaging. Every layer has its respective function, and the whole package barrier property is the key factor relating to moldiness, moistening, and flavor protection. The outer transparent film, i.e., cigarette film is of the highest barrier property among all the packaging materials, which has the closest relationship with the cigarette quality. Now, BOPP (bi-axially oriented polypropylene) film has been widely applied as the cigarette film. Though inferior in barrier performance against oxygen, BOPP film is superior in flavor protection and barrier property against moisture. Yet, with the higher requirements from the high-end cigarette packaging, the barrier performance of BOPP cigarette film, especially flavor protection performance can not meet the demands completely. Thus, high barrier film with PVDC coating has been gradually used in cigarette packaging. Besides, cigarette film should be suitable for high-speed packaging line; and a set of index requirements for coefficient of friction, thickness, shrinkage, heat seal, anti-static electricity and mechanical performances, should be achieved.
2.    Testing Items for Cigarette Film
Barrier property is the key testing item for cigarette film. Relevant tests include water vapor transmission rate testing, oxygen transmission rate testing and organic gas transmission rate testing, all of which directly relate to the moistening, moldiness and flavor protection effect of the cigarette. Meanwhile, in order to meet the requirements for high speed packaging line and packaging speed with excellent performances, the film should meet the requirements for the following indexes, namely, coefficient of friction, thickness, shrinkage, heat seal, anti-static electricity and mechanical properties, etc. Furthermore, as to the artistic and beautiful packaging demand, transparency, stiffness and haze should satisfy high standards. For this purpose, tests for coefficient of friction, heat shrinkage and thickness are of key importance.
2.1 Water Vapor Transmission Rate Testing
In order to avoid deterioration caused by moistening, higher barrier property against water vapor is required for cigarette packaging. Currently, weighing method and sensor method (including humidity sensor method, Infrared sensor method and electrolytic sensor method) are the two testing methods for water vapor transmission rate testing. Both of those two methods can meet the testing demands for cigarette films. As to testing efficiency, sensor method, especially the electrolytic sensor method, is better.
2.2 Flavor Protection Testing
Oxygen transmission rate testing is one of the common testing items for BOPP cigarette film. However, oxygen doesn’t have the influence as important as water vapor on cigarette quality. Generally, a comprehensive set of tests both for oxygen and water vapor transmission rates can help determine the flavor protection performance. It’s known that flavor is composed of organic gases. So, the flavor protection properties of different packaging materials should be evaluated based on the organic gas transmission rate testing. Yet, the test is still at its primary stage worldwide.
A lack of testing method and instruments has led to the above-mentioned comprehensive test set as a common practice to compare the flavor protection capabilities between materials. Owing to the characteristics of organic gases, including transmission characteristics, which are different remarkably from the inorganic gases, such comparison is lack in accuracy: first, swelling would occur when organic gases transmit through high polymers, and would lead to great changes to barrier properties. Second, size and characteristics of organic gases differ greatly from inorganic gases. The testing methods for organic gases have remarkable differences for those for inorganic gases, among which the biggest difference is that an organic gas generator should be preinstalled inside the instrument for low gas concentration and other characteristics of organic gases. Generally, the influence of swelling towards barrier property can be neglected if the testing gas concentration at the high concentration side is no higher than 100ppm.
There have been growing testing demands for organic gases in spite of the testing difficulties. Since 2007, Labthink Instruments has been researching on the equilibrium method for organic gas testing. Now, the professional equilibrium method organic transmission rate tester, Labthink PERME OR2/410 Organic Gas Transmission Rate Testing System has been developed successfully. This instrument is highly automatic, and convenient to operate. It meets the testing demands for flavor protection, and provides technical support for the drafting of relevant national standards.
2.3 Coefficient of Friction Testing 
In order to achieve stable and smooth operation, as well as good packaging effects for BOPP film on the cigarette packaging machine, the film should possess proper coefficient of friction. First, the side in direct contact with machine should have low coefficient of friction against metal, and the side in contact with the cigarette paper packaging should have a high coefficient of friction, so as to realize different slide capabilities between the two sides for good positioning of the cigarette packaging on the forming wheel, as well as to improve folding performance and to achieve compact packaging effect. In manufacturing process, film would slide on the film input channel, forming wheel, folding panel, welding iron, slide way and other metal parts operating in the high temperature of around 50 degree, much higher than the common testing temperature for coefficient of friction, i.e., 23 degree. Testing data indicates that, with the temperature increase, the coefficient of friction for films would increase, and even stick-slip would occur. Therefore, coefficient of friction testing in ambient temperature and its data is of little practicability for BOPP cigarette film, and the data at 60 degree is usually the necessity.
2.4 Heat Shrinkage Testing
BOPP cigarette film is usually classified into two types: standard type and heat shrinkage type. As to the standard type BOPP film, the heat shrinkage performance is not so good. The relevant heat shrinkage rate is 3%-7%. Thus, standard BOPP film is commonly used for the retailing package and bar package. On the other hand, the heat shrinkage rate of heat shrinkage BOPP film is usually greater than 8%. The cigarette package with such material can perform compact and smooth packaging effect in the long term. Heat shrinkage rate is mainly applied to evaluate the thermal stability of BOPP cigarette film in its size caused by varied conditions or factors. At present, ASTM D2732 and GB/T 13519 are the main references for this item; and heat shrinkage tester is the corresponding testing apparatus. Moreover, relevant parameters can be changed according to actual application, so as to obtain better testing results.
2.5 Thickness Testing
Thickness is a key index for BOPP cigarette film manufacturing, testing and application. If thickness can not be well controlled, flaws of outward appearance and problems for application would occur. Thicker film can have better performance in the packaging machine with better stiffness and superior package outline. However, costs would increase for such thicker films. In order to lower the packaging costs, the best parameters for excellent packaging effects with less packaging costs is under research. Yet, the practicality of the most favorable parameter is determined by the film smoothness. Furthermore, BOPP film has certain elasticity, and the mechanical determination method is more suitable for thickness testing.
3. Conclusions
The properties of cigarette packaging materials are the key factors affecting the storage period in relation to the different storing environments. According to analysis, flavor protection and water vapor barrier property are the key factors affecting cigarette storage. Now, testing technologies for water vapor and inorganic gas transmission rate have become mature; yet, the testing technologies for organic gas transmission rate relating to flavor protection is still at the development stage. It’s pleased that the domestic testing technologies for organic gas transmission rate have become world leading, and have contributed to the industrial progress.

2014年1月21日星期二

The Year of the Horse 2014

2014 is the Year of the Horse according to Chinese zodiac. The Year of the Horse starts from Jan. 31, 2014 (the Lunar New Year / Spring Festival of China) and lasts to Feb. 18, 2015.

The Chinese Zodiac, known as Sheng Xiao, is based on a twelve year cycle, each year in that cycle related to an animal sign. These animal signs are the rat, ox, tiger, rabbit, dragon, snake, horse, sheep, monkey, rooster, dog and pig. It is calculated according to Chinese lunar calendar.


The spirit of the horse is recognized to be the Chinese people's ethos – making unremitting efforts to improve themselves. It is energetic, bright, warm-hearted, intelligent and able. Ancient people liked to designate an able person as 'Qianli Ma', a horse that covers a thousand li a day (one li equals 500 meters).

People born in the year of the horse have ingenious communicating techniques and in their community they always want to be in the limelight. They are clever, kind to others, and like to join in a venture career. Although they sometimes talk too much, they are cheerful, perceptive, talented, earthy but stubborn. They like entertainment and large crowds. They are popular among friends, active at work and refuse to be reconciled to failure, although their endeavor cannot last indefinitely.

In the year of the horse, to all of you, Labthink wish this year brings to the warmth of love and illuminates your path of life towards a positive direction.

2014年1月6日星期一

6 Stations Lasting Adhesive Tester for Adhesive Tapes

6 Stations Lasting Adhesive tester
Lasting adhesive tester

Lasting Adhesive tester is designed and manufactured according to GB4851, compatible with ASTM D3654, and specially designed for adhesives, adhesive tapes, adhesive products and related industries. It is applicable in the holding power test of pressure sensitive adhesive tapes.

The Parameters

ItemsLasting adhesive tester
Standard Roller2000 g ±50 g
Weight1000 g ±10 g (with load plate)
Test Plate60 mm (L) x 40 mm (W) x 1.5 mm (D)
Timing Range0 ~ 100 h (standard)
0 ~ 10000 h (optional)
Number of Stations6


Method
1.Paste tape to steel panel
2.hung standard load on lower end
3.Keep status sometime

Three Fogging Test Methods for Automotive from Labthink

Materials used in vehicles, such as plastics, fabrics, rubber or leathers, will evaporate under high temperatures and condense on the windshield and create a fog, which causes dangerous driving conditions. Fogging test is right to measure fogging characteristics of these automotive interiors as well as HID lamps.

Three Fogging Test methods


  • Gloss Method

the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value could be obtained by calculating and comparing the gloss values occurred before and after condensation process.
  • Haze Method 
the specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value of the specimen could be obtained by calculating and comparing the fogging values occurred before and after condensation process.
  • Weighing Method 
the specimen is heated in the beaker and its volatile constituents are condensed on the cooling aluminum foil. The fogging value - the weight of condensed constituents could be obtained by analyzing the weight changes of aluminum foil occurred before and after condensation process.


FT-F1 Fogging Tester, designed and manufactured by Labthink Instruments Co., Ltd, is right designed for the fogging characteristics evaluation of volatile constituents of decorating materials used in cars and aircrafts, e.g. plastic articles, polyurethane, textiles, leather, adhesives, nonwovens and thermal forming elastomers at high temperature conditions. It also could be used for the fogging phenomenon test of high intensity discharge (HID) headlamps of cars.

This fogging tester is equipped with wide Wide range and high precision of temperature control device, which supports the combinations of non-standard test conditions 
  

More info about fogging test, please contact Labthink via 531-85060139.